T1 - The Femoral Epicondylar Frame to track femoral rotation in optoelectronic gait analysis
AU - Zurcher, A.W.
AU - Wolterbeek, N.
AU - Valstar, E.R.
AU - Nelissen, R.G.H.H.
AU - Poll, R.G.
AU - Harlaar, J.
PY - 2011
Y1 - 2011
N2 - Relative movement of skin markers to underlying bone limits a valid interpretation of axial femorotibial rotation in noninvasive optoelectronic gait analysis. A distal femoral clamp is a practical solution for thigh marker placement, however, existing devices are still susceptible to measurement errors at increased angles of knee flexion. We developed the Femoral Epicondylar Frame (FEF), which should result in less femoral rotational measurement error due to its anatomic fitting and controlled pressure adjustment. Seven subjects with a total knee replacement in situ, mean age 71 years, mean body mass index 28, were equipped with the frame mounted with a set of tantalum markers. Fluoroscopic data was collected during a step-up motion. A three-dimensional model fitting technique was used to compare the in vivo position and orientation of the frame and the femoral prosthesis component of the prosthesis. The frame rotational measurement error appeared to be linearly dependent on the knee flexion angle. When considering knee flexion angles lower than 40° of flexion, the highest measurement error was 3.3° on average, with an absolute extreme of 6.2° It is concluded that the accuracy of the FEF is sufficient to evaluate axial knee rotation with optoelectronic gait analysis at group level in clinical studies. © 2010 Elsevier B.V.
AB - Relative movement of skin markers to underlying bone limits a valid interpretation of axial femorotibial rotation in noninvasive optoelectronic gait analysis. A distal femoral clamp is a practical solution for thigh marker placement, however, existing devices are still susceptible to measurement errors at increased angles of knee flexion. We developed the Femoral Epicondylar Frame (FEF), which should result in less femoral rotational measurement error due to its anatomic fitting and controlled pressure adjustment. Seven subjects with a total knee replacement in situ, mean age 71 years, mean body mass index 28, were equipped with the frame mounted with a set of tantalum markers. Fluoroscopic data was collected during a step-up motion. A three-dimensional model fitting technique was used to compare the in vivo position and orientation of the frame and the femoral prosthesis component of the prosthesis. The frame rotational measurement error appeared to be linearly dependent on the knee flexion angle. When considering knee flexion angles lower than 40° of flexion, the highest measurement error was 3.3° on average, with an absolute extreme of 6.2° It is concluded that the accuracy of the FEF is sufficient to evaluate axial knee rotation with optoelectronic gait analysis at group level in clinical studies. © 2010 Elsevier B.V.
U2 - 10.1016/j.gaitpost.2010.11.015
DO - 10.1016/j.gaitpost.2010.11.015
M3 - Article
SN - 0966-6362
VL - 33
SP - 306
EP - 308
JO - Gait and Posture
JF - Gait and Posture
IS - 2
ER -